2025.2#
Licenseplate detection (ANPR)#
Two-Line License Plates (New)#
The license plate recognition system now supports two-line EU vehicle license plates, which are primarily used on motorcycles. This is an ideal enhancement for the solutions parking and traffic flow.
👉 Details on BCA datasheet.
Example: Two-Line License Plate
Single-Line License Plates (Improved)#
The recognition accuracy for single-line license plates has been further optimized, encompassing both license plate recognition and the detection of country and region.
Example: Single-Line License Plate
ANPR Calibration#
A new calibration function helps you achieve optimal results. It enables:
- Optimization of mounting and alignment
- Precise positioning of the crossing line
- Diagnosis of recognition quality
👉 Details on ANPR Calibration
Note
The license plate recognition is available for the products BCA, B101, and B401, and requires a device update.
Data Center#
Speed Estimation#
Speed data is used for the analysis and visualization of vehicle speeds for a selected turning movement. This turning movement must be configured accordingly to display speeds.
Temporal Progression#
This module shows the temporal progression of estimated vehicle speeds for the following percentiles: 5%, 15%, 25%, 50% (Median), 75%, 85% (v85), 95%. This data can be filtered by time using the red slider at the bottom, and by class using the toolbar on the left.
Cumulative Distribution#
This module shows the cumulative frequency of speeds over the observed period. Here, too, the data can be filtered by time and by class.
👉 For more information, please refer to the solution traffic counting.
Minor Improvements & Bug Fixes#
- API Rate Limit: Each API token is now limited to 100 requests per minute.
- The Traffic Flow API documentation has been updated.
- Downloads could previously lead to corrupted Excel files. This has been resolved.
- Events generated by rules are now processed correctly.
Control Center#
Simplified Configuration of Event Triggers#
The configuration of trigger options has been simplified and can now be done directly in-place – without additional dialogues or navigation steps.
Minor Improvements & Bug Fixes#
- A warning is now displayed for doubly assigned potential-free contacts (BMC or Quido).
- Rules with the conditions "starts with," "ends with," or with occupancy status "free" are now functioning as expected again.
BMA#
The BMA is now also available in a 48V DC variant. This expansion offers you greater flexibility for integration into existing infrastructures and power supply concepts.
👉 Datasheet